Clinical Case

Software

3m read

Common Pitfalls in Guided Full Arch Cases and How to Avoid Them

Avoid common pitfalls in full arch cases with tips for better imaging, planning, and guide design

Dr. Rowida

on

Oct 15, 2024

Common Pitfalls in Guided Full Arch Cases and How to Avoid Them

Full arch cases are among the most complex and demanding procedures in restorative and implant dentistry. These cases require meticulous planning, precision, and coordination to achieve predictable, long-term success. However, even experienced clinicians can encounter challenges that may compromise outcomes. This blog will explore some of the most common pitfalls in full arch cases and provide practical strategies to avoid them, ensuring optimal results for you and your patients.

  1. Inadequate Pre-Operative Planning

    One of the most critical mistakes in full arch cases is insufficient pre-operative planning. Inadequate planning can lead to improper implant placement, insufficient bone support, and poor esthetic outcomes. Skipping steps like detailed case evaluation, imaging, and treatment simulation often results in last-minute adjustments and compromises.

    To avoid this adopt a prosthetic-driven approach to planning, where you start by envisioning the ideal final prosthesis and work backward to determine the optimal implant positions. Using Atomica Guided Surgery Suite, you can take advantage of AI-generated virtual crowns to visualize the prosthesis first. This allows you to plan the entire treatment around the final restorative outcome, ensuring that implant placement supports both function and esthetics.



    Once the prosthesis design is established, select the most suitable implant size and type to support it. The Atomica integrated implant library enables you to virtually visualize and compare multiple implant options to identify the most appropriate choice for each specific case.



    Furthermore, planning the abutment is crucial; it must be carefully selected to fit both the implant and the desired prosthetic angulation. Atomica allows you to adjust and test various abutment angles virtually during the planning phase to ensure proper alignment with the prosthesis.

     


    By meticulously planning all these elements—the prosthesis, implant positions, implant sizes and types, and abutment angulation—you ensure that your preoperative strategy is comprehensive and data-driven, significantly reducing the likelihood of intraoperative adjustments and enhancing the overall success of the case.


  2. Challenging Calibration

The precision of guided implant surgery is determined by the deviation between the planned and actual implant positions. This accuracy encompasses a quantitative assessment of positional and angular discrepancies in three-dimensional coordinates. Implant planning software is essential for preoperative planning and the creation of customized surgical guides. However, variability in guided implant surgery accuracy can occur due to both intrinsic and extrinsic errors. Effective calibration is key to minimizing these errors in both static and dynamic guidance.

Calibration involves ensuring that the virtual and clinical environments align. This process requires calibration at two critical points: first, when transferring data from the clinical setting to the digital platform, and second, when translating digital plans back to the patient's physical mouth. Each transition introduces potential for errors that can impact the final implant position.

Data Transfer from Clinical Field to Software (Patient to Software)

This crucial stage involves registering and integrating data within the software to ensure accurate implant planning. Data registration starts with capturing impressions, typically represented by STL files, and obtaining imaging through cone-beam computed tomography (CBCT). At this stage, various factors can introduce errors, including the choice of impression materials, impression techniques, casting methods, CT machine selection, and scanning protocols. The precision of these elements is vital for accurate data integration.

The Atomica S200 intraoral scanner plays a significant role in this process by allowing for high-accuracy full arch impressions, even in cases where the patient is completely edentulous.

Also The Atomica guided software enhances this process by ensuring seamless calibration with all types of CT machines and supporting both STL and OPL file formats.

Accurate alignment of STL models with CBCT scans is critical for effective implant planning. The matching process involves automatic algorithms that align the digital impression data (STL files) with the three-dimensional volumetric data from the CT scan. High precision in this alignment is necessary to ensure that the virtual model accurately reflects the anatomical structures of the patient.

The Atomica software enhances this process by providing highly accurate automatic matching of STL models to CBCT scans, which is critical for precise implant planning. The software also includes features that allow for detailed cross-sectional checks and manual editing of any discrepancies between the digital models and the CT scans. This capability ensures that any mismatches or errors can be corrected, maintaining the accuracy of the implant planning process.

In cases where patients are fully edentulous, achieving precise matching between STL and CT data can be challenging due to the lack of anatomical reference points. To address this, the dual scan technique is employed. This technique involves capturing two separate scans: one for the patient while wearing a well-fitting denture with radio-opaque markers and the other for the denture . The dual scans are then aligned to ensure that the digital models accurately reflect the positional relationship between the denture and the underlying anatomical structures.

Then Atomica offers a solution by ensuring optimal matching of dentures to CT scans with exceptional accuracy. This technique allows for rapid and precise alignment, achieving high accuracy in just seconds.

Potential Errors during Data Transfer from Software to Patient (Software to Patient)

 Errors in implant placement can occur if the surgical guide is not correctly positioned or immobilized in the patient's mouth during surgery, particularly in edentulous cases. Human error may affect various workflow steps, and continuous monitoring of the guide's fit is essential to accurately translate the planned implant position to the surgical field. Studies have documented deviations beyond acceptable ranges, with surgical guide movement during surgery being a possible cause. The fit of the guide is generally better on dentate ridges due to the presence of teeth compared to edentulous ridges, where soft tissue can affect template stability. Increased mucosal thickness can also impact template positioning accuracy.
Here are several considerations to take care of to avoid those errors:

Fixation Pins: Securing the Guide

Fixation pins play a pivotal role in stabilizing the surgical guide during the procedure. Proper design and strategic placement are essential to prevent any movement that could affect the implant positions. The pins should be placed in areas that do not interfere with the surgical field or the planned implant sites. Atomica Suite enhances this process with its integrated fixation pins library and sleeving option, allowing for precise selection and placement of fixation pins. This feature ensures that the guide remains stable and aligned throughout the procedure, improving overall accuracy

Sleeves: Ensuring a Precise Fit

Sleeves are integral to guiding drills and must be precisely matched to the drill sizes used during surgery. Any mismatch can lead to inaccuracies in implant placement. Atomica Suite addresses this need with its integrated sleeves library, which accommodates all implant systems. Whether using specific manufacturer sleeves or generic options, the library allows for adjustments to fit the implant plan and is automatically aligned with implant placement control levels. This ensures that the sleeves provide a secure and accurate guide for the drills.

Drills: Calibration, Compatibility, and Design Enhancements

Drills are crucial in ensuring accurate implant placement, but their effectiveness depends on several factors. Fractures of surgical guides are a common intraoperative complication, often resulting from improper force application. To avoid these issues, the drill should be inserted into the sleeve before activating the motor. Additionally, the drill should be positioned centrally and parallel to the internal wall of the sleeve to ensure precise drilling.

 Tolerance issues can arise when surgical implant instruments experience gaps within metal sleeves. This gap can lead to rotational movement of the drill within the sleeve, resulting in unwanted lateral osteotomy if the drill is not aligned properly. Conversely, excessive tolerance can generate friction that hinders the drilling process, potentially leading to sleeve deformation or disintegration.

 To address these challenges, several drilling systems have been designed with shank-modified drills. These drills feature a widened shank that fits snugly within the guide sleeve, reducing tolerance and improving the accuracy of implant positioning. This modification eliminates the need for additional metal guide components, thereby enhancing the overall precision of the drilling process.

 Incorporating depth control into drills is another essential feature for improving guide system performance. A stopper is used to physically limit the depth of the osteotomy, allowing drill advancement only up to the stopper's level. This depth control is critical for preventing drills from inadvertently intruding into vital anatomical structures, such as the maxillary sinus and the inferior alveolar nerve.

 For optimal accuracy and safety, final implant insertion can be efficiently planned using the implant placement control option in Atomica Planner software. This feature ensures that implant placement aligns precisely with the planned positions, enhancing the overall success of the procedure.

Guide Parameters and Printing Considerations

The accuracy of a surgical guide also hinges on the quality of its fabrication. Atomica's design app simplifies this process by automatically adjusting guide parameters based on the selected printer and printing materials, in line with manufacturers' recommendations. This ensures that the guide meets the required standards for fit and functionality. Adhering to printer specifications and using high-quality, biocompatible printing materials further enhances the guide's precision. Post-processing and thorough inspection are also crucial to ensure that the guide performs effectively during the procedure.

  1. Poor Bone and Soft Tissue Management

In full arch implant cases, achieving adequate bone reduction and managing soft tissues effectively are crucial to ensuring the proper fit of the prosthesis and achieving desirable esthetic results. Inadequate bone reduction can result in insufficient vertical space for the prosthesis, causing poor fit, increased stress on the implants, and compromised esthetics. A precise, flat, and even bone surface is essential to provide a stable foundation for the prosthetic restoration. Proper soft tissue management, including flap design, reflection, and suturing, is equally important to ensure optimal healing and prevent complications such as dehiscence, peri-implantitis, and soft tissue recession.

Utilizing advanced digital planning tools allows for a more accurate calculation of the required bone reduction, ensuring optimal prosthetic space and stability. The Atomica stackable guide module offers a bone reduction guide that is specifically designed to assist clinicians in achieving precise levels of bone reduction. This guide integrates with digital planning software to translate virtual plans into the clinical setting, ensuring the appropriate amount of bone is removed to achieve the ideal foundation for the prosthesis. Additionally, this guide can help maintain consistency in reduction levels across multiple sites, improving the predictability and accuracy of surgical outcomes.

  1. Poor Communication with Colleagues and laboratory

Miscommunication with the dental laboratory can create numerous challenges in full arch cases. Small errors, like incorrect shade matching or poor-fitting prostheses, can significantly impact the final outcome, resulting in wasted time, resources, and potentially compromising patient satisfaction. To avoid these pitfalls, it is crucial to establish a seamless communication protocol that ensures the lab has all necessary details upfront. Atomica offers a comprehensive solution by providing a detailed drilling report that includes all planned data, 3D models, and digital instructions, allowing the lab to fabricate precise, custom-fit prosthetics.

Also the ability to transfer high-resolution intraoral scans and treatment plans directly through software eliminates guesswork, reduces errors, and ensures a clear understanding of clinical requirements.  With Atomica S200 portal you can also share all your patient scans seamlessly to your lab and colleagues. Regular check-ins and virtual meetings using shared digital files can further align expectations, streamline workflows, and enhance overall collaboration between clinicians and lab technicians.

  1. Poor Communication with Patients

For patients, clear communication about their treatment plan is essential to building trust and ensuring satisfaction with the final result. In full arch cases, where treatments can be complex and involve multiple stages, patients may feel anxious or confused about what to expect. Atomica helps bridge this communication gap by using virtual elements and detailed 3D models that provide a visual representation of the planned outcomes. Patients can see a digital illustration of their final prosthesis, helping them better understand the procedure and the anticipated results. This transparency not only fosters trust but also allows patients to give informed consent, ask questions, and feel more comfortable throughout the treatment journey. Additionally, with the detailed drilling report and data available, clinicians can explain each step of the procedure in an understandable way, reinforcing the patient's confidence in the process and ensuring they feel engaged and informed at every stage of their care.

Conclusion

Full arch cases are complex, but with the right tools and strategies, you can navigate these challenges successfully. Avoid common pitfalls by leveraging advanced digital tools like the Atomica Guided Surgery Suite and the S200 Intraoral Scanner to improve planning, execution, and outcomes. Remember, careful preparation, clear communication, and consistent follow-up are key to delivering predictable, high-quality results that meet both your clinical standards and your patient's expectations.

Ready to elevate your full arch cases? Discover how the Atomica Suite can transform your practice, book a demo today!