AtomicaUser Guide

Designing Guides

Learn more about our Guide Design software, Learn how to design surgical guides effortlessly with Atomica’s intuitive step-by-step user guide.

Automated guide design

Select the model, and from the Generate guide module Click Start. Choose the Guide Type. Choose the printer you will use, and the measurements will be automatically adjusted, or choose custom printers and manually adjust the guide measurements.  Make sure that undercut generation is automated.  The selection tools will be automatically activated. Choose the Guide selection tool. Mark the first and last teeth in the guide seating area. The guide seating area will be marked. Make manual edits if needed using the brush selection tool. Click Generate guide. 

Automated Guide Design

Editing Implant Position in the Design App

The Design app allows implant positions to be adjusted directly during the guide design stage, enabling precise, design-driven implant placement without returning to the planning stage.

  • Right-click on the implant.

Customizable Sleeve Reinforcement

  • Mark the sleeve you want to reinforce.

  • Change the dimensions (length and thickness) as needed.

  • Apply the reinforcement to optimize guide strength for your case and printing preferences.

  • You can also change the dimensions using the gizmo tool

    Easier Material Editing Around Sleeves

Glue hole

This is a tool to open a hole in the guide to allow the excess glue used to secure the sleeve our of the guide. Click on Glue hole and a small sphere will be added to the working field. Move the sphere to the desired location and click apply.

Glue Hole

Timing

This is a tool to mark the proper position at which you should stop the implant insertion. Select the implant, click ctrl, and select the guide, and the timing tool will be activated. According to your implant system, mark the correct position of ‘timing’ and click apply.

Timing

Timing for Multiple Models

The Timing Tool can now be applied to multiple models simultaneously—mark your guide and analogue model at the exact same time. Mark both models and apply timing.

Multi-Model Timing

Buccal window

For system that requires lateral insertion and for patients who have limited mouth opening you can open a buccal window in the guide to make a buccal path for the drill. Mark the implant and choose Buccal window, then move the cube to the position you want and adjust it's depth and click apply.

Buccal Window

Buccal Window Customization

More control and flexibility when designing buccal windows for better visibility and irrigation.

Buccal Window Customization

Designing Printable Cast

To create a base for a model, mainly for designing a printable cast, select the model and choose Create Base. Automatically detecting undercuts and hollow base will be marked, which gives you optimum choices for casts’ printing. But if you need to deactivate these options for any reason, just unselect them before creating the base.

Automatic base

Also all the holes in the model will be automatically filled except the biggest hole to speed up the design process.

Auto fill for holes

Articulator Attachment Tool

  • In the 3D scene, click to mark the first model. Hold the CTRL key and click the second model to ensure both are selected for the attachment.

  • Navigate to the Advanced Tools menu and select Articulator Attachment.

  • From the tool options, select the specific type of attachment required for your articulator system.

  • Hover your cursor over the desired location on the 3D scene and click to place the attachment.

  • Once placed, left-click the attachment to activate the Gizmo to refine the position and orientation.

Articulator Attachment Tool